APE-2BXL+24+GAS
TRAPPED PERSON ALARM WITH BATTERY AND GAS LEAK WITH 24V OUTPUT for powering Glaciär, DGD detectors.
Mandatory compliance solution for freezing and refrigerating chambers.
Application: One Freezing Chamber; Spanish standards specify (2 circuits, one with 10-hour battery and one redundant).
Application: TWO Refrigeration Chambers at 0..+5 ºC. Standards specify (single call bell) for the two identified circuits on the front panel, each monitoring one chamber.
Gas Leak Detection: Mandatory for volumes ≥ 10 m³.
Complies with regulations RD 552/2019 and EN378-1, EN378-3. Optical and acoustic signaling at 90 dB.
Includes 2 emergency illuminated push buttons, 2 control units (1 with battery and 1 without), 2 auxiliary relays (1 per circuit), removable terminals. TTL, Rs485 plug & play connectable to Glaciär and DGD sensors, 2 digital inputs (1 per circuit) configurable to NTC temperature probe. Programmable functions per circuit: door open or temperature alarm or gas detection maneuvers controlled from PLC, etc. Dimensions: 150 x 200 x 80 mm. Power supply at 230 Vac. New 360Surveillance feature for controlling people, food, products, refrigeration failures,and power supply (battery-operated only).
Legend:
(code APE-2BXL+24+GAS) with 24VDC output
(code APE-2BXL+GAS) gas detector powered externally
code + Gas (choose Gas Detector...see models), optional
code + 24 (includes 24VDC output for gas detectors), optional
code B (removing 'B' from code excludes Battery), optional *not compatible in freezing
code Cent. (adding initials, example: "Cent."APE2-XL is control unit only, "Cent."APE2-BXL control unit with Battery)
Examples: APE-2BXL+24, APE-2BXL+24+GAS, APE-2XL+24, APE-2XL+24+GAS...